Trouble Setting Windows 7 Embedded System Name to Asset Tag
Has anyone else had this issue? I am deploying a sysprep'd & captured HP Windows 7 Embedded Standard image through SCCM. As part of the deployment task sequence I set the OSDCOmputerName Variable to be be the SMBIOSAssetTag value...this works great on normal systems running W7 Enterprise yet on the HP Thin Clients with WES the computer name is not retained (despite all logs stating the computer name is the AssetTag). Once built the system name is something like - HP-123344FRHE - I suspect this a registry key somewhere changing the name, can anyone confirm my suspicions? I hope this makes sense. . Can anyone shed any light? Thanks Richard.
September 10th, 2012 7:22am

Resolved.... There were HP unattend files in the panther and sysprep folders which were causing the problem. Once removed the image deploys and names the system correctly as the asset tag. Richard.
Free Windows Admin Tool Kit Click here and download it now
September 10th, 2012 2:36pm

This topic is archived. No further replies will be accepted.