HP ProLiant Smart Array configuration during deployment with SCCM 2012 with ACU problem

Hello

I am making a OSD from HP ProLiant Gen 8 microservers.

I made an ACU script for making Smart array and logical disks, I made a capture of the existing configuration using hpssascripting -c:

Action= Configure
Method= Custom


Controller= SLOT 0
RebuildPriority= Medium
SurfaceScanMode= Idle
SurfaceScanDelay= 3
DriveWriteCache= Disabled
PredictiveSpareActivation= Disable

Array= A
Drive= 1I:0:1, 2I:0:2
OnlineSpare= No

LogicalDrive= 1
RAID= 1
Size= 953837
Sectors= 32
StripSize= 256
Caching= Enabled

When I put this script in the task sequence, it executes, but when it fails when getting to the step Apply Operating System.

Error log will say it has no bootable partition. 

When I do diskpart, I can see the disk and the partitions.

The weird thing is when I manually make the array in the Smart Array Administrator, it works fine.


  • Edited by DoubleT10 22 hours 17 minutes ago
March 27th, 2015 5:25am

Fixed, a reboot was required.
  • Proposed as answer by Narcoticoo 16 hours 34 minutes ago
Free Windows Admin Tool Kit Click here and download it now
March 27th, 2015 10:34am